GSVM-12 Switch Features
1.Three-phase split design eliminates the risk of inter-phase short- circuitfaults.
2.The insulation surface uses a unique arc-sprayed zinc process,achieving full grounding, full shielding, and a touchable surface.
3.Carbon fiber shielding layer balances electric field distribution and improves heat dissipation efficiency.
4.The switch configuration adopts an upward isolation scheme, fully compliant with SGCC standardized specifications.
1.Three-phase split design eliminates the risk of inter-phase short- circuitfaults.
2.The insulation surface uses a unique arc-sprayed zinc process,achieving full grounding, full shielding, and a touchable surface.
3.Carbon fiber shielding layer balances electric field distribution and improves heat dissipation efficiency.
4.The switch configuration adopts an upward isolation scheme, fully compliant with SGCC standardized specifications.
Quantity
-
Detail
Operating Conditions
GSVM-12(V)Altitude≤2000m
TemperatureMaximum55℃Minimum-40℃Average within 24h≤35℃HumidityAverage relative humidity within 24h≤95%Monthly average relative humidity≤90%EnvironmentSurrounding air free of explosive, corrosive gases,installation site free of severe vibration and impact
Notes
Please contact us for requirements exceeding the above conditions.
GSVM-12 SeriesThe GSVM series solid-insulated switch complies with the Standardized Design Scheme for10kV Ring Main Units (RMUs), featuring core design innovations:
1. Segregated Three-Phase Structure:
Each phase's conductive path and insulation are independentlyencapsulated, significantlyenhancing interphase dielectric strengthand effectively preventing phase-to-phase shortcircuit faults.2. Advanced Surface Treatment Technology:A proprietary arc zinc fusion process is applied to the epoxy insulationsurface of core units,creating a uniform, dense metallic zinc coating. Thisachieves:1.Full shielding & Grounding Design: Forms an equipotentialgrounding shield layer to equalize electric field distribution andsuppress partial discharge (PD).2.Safe-to-Touch Surface Characteristics: Ensures personnel safetyduring operation.3.Enhanced Surface Protection: Metallurgically bonded zinc-epoxycomposite forms arobust, dense insulation structure.3. Superior Environmental Resilience:The solid insulation combined with zinc shielding effectively withstands insulation degradationcaused by contamination, humidity, condensation,and other harsh environmental factors.Collectively, these designs ensure exceptional dielectric reliability, provide robustassurance for long-term stable operation, and deliver significantly elevated overall safetyperformance.
Primary CircuitCircuit Breaker• Employs vacuum arc-extinguishingtechnology to ensure high breakingcapacity and long electrical life.• The transmission system's shaft supportextensively uses needle roller bearingdesign, ensuring flexible rotation and hightransmission efficiency.Disconnector• Three-position design theoreticallyeliminates the occurrence of misoperations.• Air distance between the isolation bladeand grounding contact/stator contact is125mm, ensuring insulation reliability.• High-performance disc springs ensurestability of contact pressure.• Contact design favorable for closing shape,grounding closing speed ≥4.2m/s, ensuringgrounding closing reliability
Operating Mechanism
Circuit Breaker Mechanism• Five-link mechanism transmission designwith reclosing function.• The planetary deceleration DC permanentmagnet motor has a small volume, stableoperation and an amazing transmissionefficiency of about 3% energy loss.• Components like the main switch's motor,auxiliary switch, release, and limit switchare readily replaceable.• Dual-spring precision transmission designwith reclosing function.• All transmission components are made of high-quality quenched and tempered steeland hardened steel,ensuring a long servicelife.• Core transmission uses needle rollerbearing design, offering strong impactresistance, high load capacity, and lowfriction.Disconnector Mechanism• Isolation mechanism uses a torsion - spring - based quick - acting mechanism, achieving the three positions "Close, Open, Ground"(standard three - position states fordisconnectors) through torsion springforward/reverse rotation.• Rigid bidirectional mechanical limit designat the isolation position ensures precisepositioning of the isolation position(Open/Close states), preventing displacement due to external force.• Rigid mechanical interlocking for five -prevention functions reliably preventsmisoperation.
Electrical Schematic Diagrams
Equipment NoEquipment NameQuantity-DLCircuit Breaker1 HQCircuit Breaker Closing Coil1 TQCircuit Breaker Tripping Coil1 M1Circuit Breaker Spring Energy - storage Motor1 CK1Disconnector Travel Switch1 CK2Earthing Switch Travel Switch1 CK3Spring Energized Travel Switch1 S1-1Disconnector Travel Switch1 S1-2Disconnector Travel Switch1 S1-3Disconnector Travel Switch1 S3-1Earthing Switch Travel Switch1 S3-2Earthing Switch Travel Switch1 S3-3Earthing Switch Travel Switch1 EL1Light1 
Typical Application Schemes
GSVM-12 Series Primary Main Wiring Scheme